Multi Meters
Digital Multimeters Bench type Multimeters AC milivolt meters
XB30
Display  3-1/2 Digits 1999 Counts LCD
DC Voltage 0-200mV/2V/20V/200V/1000V.
Accuracy ± 0.5 %
AC Voltage 0 - 200V / 750V
Accuracy  ± 1.2%
DC Current 0 - 200 A / 2mA/ 20mA/ 200mA/ 10A
Accuracy ± 1.0%
Resistance 0 - 200 /2K/20K/200K/2 M Ohms
Accuracy ± 1.0%
With Diode Test, Transistor test and Data Hold facility
Confirms to CE, CAT - III 600V, CAT - II 1000V, IEC 1010-1
 
XB31
Display 
3-1/2 Digits 1999 Counts LCD
DC Voltage
0-200mV/2V/20V/200V/600V.
Accuracy
± 0.5 %
AC Voltage
0 - 200V / 600V
Accuracy 
± 1.2%
DC Current
0-200 A/2mA/20mA/200mA/10A
Accuracy
± 1.0%
Resistance
0 - 200 /2k/20k/200k/20M Ohms
Accuracy
± 0.8%
Transistor Test Facility
Temperature
-20 °C to 750 °C/ -4 °F to 1400 °F
With Diode Test, Continuity test and Data Hold facility 
Confirms to CE, CAT - II 600V
 
XB32
Auto Power Off
Display  3-1/2 Digits 1999 Counts LCD
DC Voltage 0-200mV/2V/20V/200V/1000V.
Accuracy ± 0.5 %
AC Voltage 0 – 2V / 20V/200V/750V
Accuracy  ± 0.8%
DC Current 0 – 200mA /2mA/20mA/200mA/10A
Accuracy ± 0.8%
AC Current 0 – 2m /20m/200m/10A
Accuracy ± 1.2%
Resistance 0 – 200 /2k/20k/200k/2m/20m. Ohms
Accuracy ± 1.0%
With Diode Test, Transistor test and audible continuity
Confirms to CE, CAT – III 600V, CAT – II 1000V, IEC 1010-1
 
XB33C
Auto - Ranging
Auto Power Off
Display  3-1/2 Digits 1999 Counts backlit LCD
DC Voltage 0-200mV/2V/20V/200V/600V.
Accuracy ± 0.8 %
AC Voltage 0 - 200V / 2V/20V/200V/600V
Accuracy  ± 1.0%
DC Current 0 - 200  /2m/20m/200m/2A/10A
Accuracy ± 1.0%
AC Current 0 - 200  / 2m/20m/200m/2A/10A
Accuracy  ± 1.8%
Resistance 0 - 200 /2K/20K/200K/2M/20M Ohms
Accuracy ± 0.8%
Temperature -40ºC to 1000ºC -40ºF to 1832ºF
Accuracy ± 1.0% 
With Diode Test, audible continuity test & Data Hold facility 
Confirms to CE, CAT - III 600V
 
DM 603
Auto Power Off
Data Hold to freeze the displayed reading
Display  3-1/2 Digits 1999 Counts Backlit Extra Large LCD
DC Voltage 0-200mV/2V/20V/200V/1000V.
Accuracy ± 0.5 %
AC Voltage 0 - 2V /20V/200V/750V
Accuracy  ± 0.8%
DC Current 0 - 20mA /200mA/20A
Accuracy ± 0.8%
AC Current 0 - 20mA /200A/20A
Accuracy ± 1.0%
Resistance 0 - 200 /2k/20k/200k/2M/200M Ohms
Accuracy ± 0.8%
Capacitance 0-20nF / 2 F/200 F
Accuracy ± 2.5%
Temperature -40 °C to 1000 °C 
Accuracy ± 0.8% 
Frequency  0 - 2k/200kHz
Accuracy ± 3.0% 
With Diode Test, Transistor Test, Hot Wire Test and Audible Continuity test facility 
Confirms to IEC1010 CE, CAT II 1000V
 
DM 19
Data Hold to freeze the displayed data
Auto Power Off
Relative Measurement facility
Display  3-3/4 Digits 3999 Counts LCD
DC Voltage 0-400mV/4V/40V/400V/1000V.
Accuracy ± 0.5 %
AC Voltage 0 - 400mV /4V/40V/400V/750V
Accuracy  ± 0.8%
DC Current 0 - 400 A /4000 A/40mA/400mA/10A
Accuracy ± 1.0%
AC Current 0 - 400 A /4000 A/40mA/400mA/10A
Accuracy ± 1.5%
Resistance 0 - 400 /4k/40k/400k/4M/40M Ohms
Accuracy ± 0.8%
Capacitance 0-4nF / 40nF/400nF/4 F/40 F/200 F
Accuracy ± 2.5%
Frequency 0 - 100 /1000/10k/100k/1m/30MHz
Accuracy ± 0.5%
Temperature -40 °C to 1000 ° C 
Accuracy ± 0.8%
Duty cycle, Diode test, transistor test and audible continuity test
Confirms to CE, EMC / LVD, IEC1010. 
 
SS 15
Peak Hold, Relative Measuring Facility,MAX /MIN Recording, Auto Power OFF
Display  3-3/4 Digits 3999 Counts Backlit LCD with analog bargraph
DC Voltage 0-400mV/4V/40V/400V/1000V.
Accuracy ± 0.5 %
AC Voltage 0 - 400mV /4V/40V/400V/1000V
Accuracy  ± 0.8%
DC Current 0 - 400 A /4000 A/40mA/400mA/20A
Accuracy ± 1.2%
AC Current 0 - 400 A /4000 A/40mA/400mA/20A
Accuracy ± 1.5%
Resistance 0 - 400 /4k/40k/400k/4M/40M Ohms
Accuracy ± 0.8%
Capacitance 0-4nF / 40nF/400nF/4 F/40 F/400 F/ 4mF/40mF
Accuracy ± 3.0%
Frequency  0-4kHz/40kHz/4MHz/40MHz
Accuracy ± 1.2%
Temperature - 40 °C to 760 ° C / -4 ° F to 1400 °F
Accuracy ± 3%
Diode Test and audible continuity test 
Confirm to CAT -III 1000V, CAT IV 600V, EN61010-1, CE.
 
SS 16
T - RMS measurement, Peak Hold, Relative Measuring Facility, MAX /MIN Recording, Auto Power OFF
Display  3-3/4 Digits 3999 Counts Backlit LCD With analog bargraph
DC Voltage 0-400mV/4V/40V/400V/1000V.
Accuracy ± 0.5 %
AC Voltage 0 - 400mV /4V/40V/400V/1000V T-RMS
Accuracy  ± 0.8%
DC Current 0 - 400 A /4000 A/40mA/400mA/20A
Accuracy ± 1.2%
AC Current 0 - 400 A /4000 A/40mA/400mA/20A T-RMS
Accuracy ± 1.5%
Resistance 0 - 400 /4k/40k/400k/4M/40M Ohms
Accuracy ± 0.8%
Capacitance 0-4nF/40nF/400nF/4 F/40 F/400 F  /4mF/40mF
Accuracy ± 3.0%
Frequency  0-4kHz/40kHz/4MHz/40MHz
Accuracy ± 1.2%
Temperature - 40 °C to 760 °C / -4 ° F to 1400 °F
Accuracy ± 3%
Diode Test and audible continuity test 
Confirm to CAT -III 1000V, CAT IV 600V, EN61010-1, CE. 
 
SS 18
T - RMS measurement, Relative measurement, Data Hold andPeak Hold Facility, MAX /MIN Recording facility, Auto Power OFF
Display  4-3/4 Digits 39999 Counts Backlit LCD with analog bargraph
DC Voltage 0-400mV/4V/40V/400V/1000V.
Accuracy ± 0.06 %
AC Voltage 0 - 400mV /4V/40V/400V/1000V T-RMS
Accuracy  ± 1.0%
DC Current 0 - 400 A /4000 A/40mA/400mA/20A
Accuracy ± 1.0%
AC Current 0 - 400 A /4000 A/40mA/400mA/  20A T-RMS
Accuracy ± 1.5%
Resistance 0 - 400 /4k/40k/400k/4M/40M Ohms
Accuracy ± 0.3%
Capacitance 0-40nF / 400nF/4 F/40 F/400 F/  4mF/40mF
Accuracy ± 3.5%
Frequency  0-40Hz/400Hz/4kHz/40kHz/400kH/4MHz/40MHz/100MHz
Accuracy ± 0.1%
Duty Cycle 0.1% - 99.9%
Accuracy ± 1.2%
Temperature - 50 °C to1000 °C / -58 °F to 1832 °F
Accuracy ± 3%,  4 - 20mA = 0 - 100%
Infra Red  Non Contact temperature measuring range: 
-30 °C to 500 °C/-22 °F to 1022 °F
Diode Test and audible continuity test 
Confirm to CAT -III 1000V, CAT IV 600V, EN61010-1, CE.
 
DM 454
T - RMS measurement, for AC and AC + DC, Data Hold 
Auto Power OFF
Display  4-1/2 Digits 19999 Counts LCD
DC Voltage 0-200mV/2V/20V/200V/1000V.
Accuracy ± 0.05 %
AC Voltage 0 - 200mV/2V/20V/200V/750V 
Accuracy  ± 1.0%
DC Current 0 - 200 A /2mA/20mA/200mA/20A
Accuracy ± 0.5%
AC Current 0 - 200 A /2mA/20A/200mA/20A
Accuracy ± 1.2%
Resistance 0 - 200 /2k/20k/200k/2M/20M Ohms
Accuracy ± 0.25%
Frequency  0-2k/20k/200kHz
Accuracy ± 0.5%
Duty Cycle 0-99.9%
Accuracy ± 0.1%
Diode Test, Logic Test  and audible continuity test 
 
DM 23S MK-II
Data Hold 
Auto Power Off
Display  4-1/2 Digits 19999 Counts Backlit LCD
DC Voltage 0-200mV/2V/20V/200V/1000V.
Accuracy ± 0.1 %
AC Voltage 0 - 2V /20V/200V/750V 
Accuracy  ± 0.8%
DC Current 0 - 200u /2mA/20mA/200mA/20A
Accuracy ± 0.5%
AC Current 0 - 20mA /200mA/20A 
Accuracy ± 1.5%
Resistance 0 - 200 /2k/20k/200k/2M/200M Ohms
Accuracy ± 0.4%
Capacitance 0-20nF /2 F/200 F
Accuracy ± 3.5%
Frequency  0-20k/200kHz
Accuracy ± 3.0%
Temperature - 40 °C ~+1000 ° C
Accuracy ± 0.8%
Diode Test and audible continuity test 
Confirm to IEC1010-1Standards.
 
DM 97
Features:
  3 ¾ Digital Multimeter
  4000 Counts
  Large LCD Display with Auto/ Manual Range
  No Power-OFF under natural operation
  Data Hold, Max. / Min value Hold
  Capacitance, Frequency / Duty cycle, Temperature and Transistor Test
Technical Specifications:
  DC Voltage 0.1mV ~ 1000V
  Accuracy ±(0.5% + 4 digit)
  AC Voltage 0.1mV ~ 750V
  Accuracy ±(0.8% + 6 digit)
  DC Current 0.1 A ~ 20A
  Accuracy ±(1.0% + 5 digit)
  AC Current 0.1 A ~ 20A
  Accuracy ±(1.5% + 5 digit)
  Resistance 0.1  ~ 40M 
  Accuracy ±(0.8% + 2 digit)
  Capacitance 10pF ~ 200 F 
  Accuracy ±(3.5% + 8 digit)
  Frequency 0.1Hz ~ 30MHz
  Accuracy ±(0.5% + 4 digit)
  Celsius -40 °C to 1000 °C
  Accuracy ±(0.8% + 4 digit)
  hhFE (NPN / PNP) 0 ~ 1000
Special Functions
  Diode test yes
  Transistor testing  yes
  Continuity Buzzer Lower 30  ± 10 
  Low Battery display Lower 2.4V
  Auto Power OFF Approx. 30 min.
  Function Protection yes
  Input Impedance 10M 
  Sampling Rate 3 times per second
  AC Frequency Response 40 - 400 Hz
  Power F3V AAA
Standard Accessories
  Test Leads, Holster, Manual, Temperature Probe Bead type
Dimensions (mm) 185 (H) x 93 (W) x 35 (D)

 

 

 
 
* Products not listed can be ordered as per request.